0.6/1kV交联聚乙烯绝缘电力电缆 XLPE Insulated Power Cable |
|
产品标准 standard 本产品按GB12706《额定电压35KV铜芯、铝芯塑料绝缘电力电缆》标准生产,同时还可根据用户需要按国际电工委员会推荐标准IEC、英国标准、德国标准及美国标准生产。The product is manufactured according to the standard of GB12706、IEC.BS,DIN and ICEA upon request. 适用范围 Applications 本产品适用于工频额定电压64/1KV及以下配电网或工业装置中固定敷设之用。 The product is suitable for use in power distribution lines or fixed installations with rated power- frequency voltage up to and including 0.6/1Kv. 使用特性 Operating characteridtles ·工频额定UO/U为0.6/1KV。 Rated power –frequency voltage UO/U为0.6/1KV。 电缆导体允许长期最高工作温度为90℃。 Max.permissible continuous operating temperature of conductor:90℃. 短路时(最长持续时间不超过5s)电缆导体的最高温度不超过250℃。 Max.short –circuit temperature of conductor shall not exceed 250℃(5s maximum duration ). 电缆敷设时环境温度应不低于0℃。 The ambient temperature under installation should not below 0℃. 电缆弯曲半径:不小于电缆外径的15倍。 The bending radius should not less than 15 times of cable diameter.
电缆的型号 Type of cable
| 型号 Type |
名称 Designation |
适用范围 Application |
| YJV |
铜芯交联聚乙烯绝缘聚氯乙烯外护套电力电缆 Copper conductor ,XLPE insulated ,PVC sheathed power cable |
室内、隧道、电缆沟内或直脉地下,能够承受一定的机械外力和一定的拉力。 For laying indoor , in tunnel, cable French, well or direct in ground , able to bear external mechanical forces and certain pulling force. |
| YJLV |
铝芯交联聚乙烯绝缘聚氯乙烯护套电力电缆 Aluminum conductor ,XLPE insulated ,PVC sheathed power cable |
| YJY |
铜芯交联聚乙烯绝缘聚乙烯外护套电力电缆 Copper conductor ,XLPE insulated ,PE sheathed power cable |
| YJLY |
铝芯交联聚乙烯绝缘聚乙烯护套电力电缆 Aluminum conductor ,XLPE insulated ,PE sheathed power cable | |
| 电缆的型号 |
生产范围Production Range of Cable
| 型号 Type |
芯数 No.of cores |
导体标称截面 Nominal cross-section of conductor mm2 |
| 铜导体 Copper conductor |
铝导体 Aluminum conductor |
1* |
|
YJV YJY
YJV22 YJV23 |
YJLV YJLY YJLV22 YJLV23 |
2 |
1.5~800 2.5~800 10~800 |
YJV YJY
YJV22 YJV23 YJV32 YJV33 |
YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 |
3 |
1.5~300 2.5~300 2.5~300 10~300 |
YJV YJY YJV22 YJV23 YJV32 YJV33
|
YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 |
4 |
1.5~400 2.5~400 2.5~400 10~400 |
YJV YJY YJV22 YJV23 YJV32 YJV33
|
YJLV YJLY
YJLV22 YJLV23 YJLV32 YJLV33 |
3+1 |
1.5~400 2.5~400 2.5~400 10~400 |
YJV YJY YJV22 YJV23 YJV32 YJV33
|
YJLV YJLY
YJLV22 YJLV23 YJLV32 YJLV33 |
5 |
1.5~400 4.0~400 1.5~400 4.0~400 10~400 |
YJV YJY YJV22 YJV23 YJV32 YJV33
|
YJLV YJLY
YJLV22 YJLV23 YJLV32 YJLV33 |
4+1 |
1.5~400 2.5~400 1.5~400 2.5~400 10~400 |
YJV YJY YJV22 YJV23 YJV32 YJV33
|
YJLV YJLY
YJLV22 YJLV23 YJLV32 YJLV33 |
3+2 |
1.5~400 4.0~400 1.5~400 4.0~400 10~400 |
YJV YJY YJV22 YJV23 YJV32 YJV33
|
YJLV YJLY
YJLV22 YJLV23 YJLV32 YJLV33 |
|
1.5~400 4.0~400 1.5~400 4.0~400 10~400 | |
*单芯铠装电缆仅用于直流系统,若用于交流系统,应采用非磁性材料铠装或隔磁措施。 *The armoured single-core cables are used for d.c. system only.As for a.c. system,non-magnetic armour material should be used,or a magnetic isolation shouls beapplied.
结构尺寸及主要技术参数Construction and main technical data 0.6/1KV单芯交联聚乙烯绝缘聚氯乙烯护套电力电缆(YJV,YJLV) 0.6/1KV,Single-core,XLPE Insulated,PVC Shezthed Power Cable
导体标称截面 Nom.cross-section of conductor
|
导体直径 Diammeter ofconductor
|
绝缘厚度 Insulation Thickness
|
护套厚度 Sheath thickness
|
电缆近似外径 Approx. overalld iameter of cable
|
电缆近似重量 Approx.weighe of cable Kg/km
|
导体最大直流电阻 Max.d.cresis tance(20 ℃ )Ω /km
|
试验电压 Test Voltage(a.c)
|
| mm2 |
mm |
mm |
mm |
mm |
YJV |
YJLV |
YJV |
YJLV |
KV/5min |
1 × 1.5 1 × 2.5 1 × 4 |
1.4 1..8 2.2 |
0.7 0.7 0.7 |
1.4 1.4 1.4 |
5.6 6.0 6.4 |
52.4 65.4 83.1 |
50 58.8 |
12.1 7.41 4.61 |
12.1 7.41 4.61 |
3.5
|
1 × 6 1 × 10 1 × 16 |
2.8 4.1 5.1 |
0.7 0.7 0.7 |
1.4 1.4 1.4 |
7.0 8.3 9.3 |
106.7 157.7 221.6 |
69.7 94.5 121.5 |
3.08 1.83 1.15 |
3.08 1.83 1.15 |
1 × 25 1 × 35 1 × 50 |
6.4 7.6 8.9 |
0.9 0.9 1.0 |
1.5 1.5 1.6 |
11.2 12.4 14.1 |
334.7 435.8 576.7 |
175.9 215.6 278.6 |
0.73 0.52 0.39 |
0.73 0.52 0.39 |
1 × 50* 1 × 70 1 × 70* |
8.3 10.7 |
1.0 1.1 |
1.6 1.6 1.6 |
13.5 16.1 |
557.8 793.6 752.3 |
267.5 362.7 342.1 |
0.39 0.27 0.27 |
0.39 0.27 0.27 |
1 × 95 1 × 95* 1 × 120 |
12.6 11.5 14.2 |
1.1 1.1 1.2 |
1.7 1.7 1.7 |
18.2 17.1 20.0 |
1066 1028 1321 |
468.8 447.1 565.7 |
0.19 0.19 0.15 |
0.19 0.19 0.15 |
1 × 120* 1 × 150 1 × 150* |
12.9 15.8 14.5 |
1.2 1.4 1.4 |
1.7 1.7 1.7 |
18.7 22.0 20.7 |
1275 1606 1584 |
539.1 677.8 658.3 |
0.15 0.12 0.12 |
0.15 0.12 0.12 |
1 × 185 1 × 185* 1 × 240
|
17.6 16.0 20.3
|
1.6 1.6 1.7
|
1.7 1.7 1.7
|
24.2 22.6 27.1
|
1977 1868 2548
|
813.3 763.5 1018
|
0.10 0.10 0.08
|
0.10 0.10 0.08
|
1 × 240* 1 × 300 1 × 300*
|
18.3 22.7 20.5
|
1.7 1.8 1.8
|
1.7 1.7 1.7
|
25.1 29.7 27.5
|
2399 3151 3028
|
952.7 1232 1172
|
0.08 0.06 0.06
|
0.08 0.06 0.06
|
1 × 400 1 × 400* 1 × 500
|
25.7 23.5 28.8
|
2.0 2.0 2.2
|
1.7 1.7 1.8
|
33.1 30.9 36.8
|
3985 3888 4996
|
1531 1478 1902
|
0.05 0.05 0.04
|
0.05 0.05 0.04
|
1 × 500* 1 × 630 1 × 630* 1 × 800
|
26.5 32.5 29.5 36.5
|
2.2 2.4 2.4 2.6
|
1.8 1.9 1.9 2.0
|
34.5 41.1 38.5 45.7
|
4953 6294 6164 7920
|
1861 2372 2299 2592
|
0.04 0.03 0.03 0.02
|
0.06 0.05 0.05 0.04
| *表示导体为紧压圆形胶合导体。 *-Compacted stranded circular conductor. |
 |
0.6/1KV单芯交联聚乙烯绝缘钢带铠装聚氯乙烯护套电力电缆(YJV22,YJLV22) 0.6/1KV,Single-core,XLPE Insulated,Steel Tape Armoured,PVC Shezthed Power Cable
导体标称截面 Nom.cross-section of conductor
|
导体直径 Diammeter ofconductor
|
绝缘厚度 Insulation Thickness
|
护套厚度 Sheath thickness
|
电缆 近似外径 Approx. overalldia meterof cable
|
电缆近似重量 Approx.weighe of cable Kg/km
|
导体最大直流电阻 Max.d.cresistance (20 ℃ ) Ω /km
|
试验电压 Test Voltage(a.c)
|
mm2
|
mm
|
mm
|
mm
|
mm
|
YJV
|
YJLV
|
YJV
|
YJLV
|
KV/5min
|
1 × 10 1 × 16 1 × 25
|
4.1 5.1 6.4
|
1.0 1.0 1.2
|
1.8 1.8 1.8
|
11.7 12.7 14.4
|
233.3 305.8 426.4
|
170.1 205.8 267.7
|
1.83 1.15 0.73
|
30.8 1.91 1.20
|
0.35
|
1 × 35 1 × 50 1 × 50*
|
7.6 8.9 8.3
|
1.2 1.2 1.4
|
1.8 1.8 1.8
|
15.6 17.1 16.5
|
536.2 680.8 657.6
|
316.1 382.6 367.3
|
0.52 0.39 0.39
|
0.87 0.67 0.67
|
1 × 70 1 × 70* 1 × 95
|
10.7 9.8 12.6
|
1.4 1.4 1.6
|
1.8 1.8 1.8
|
19.1 18.2 21.0
|
912 864.3 1188
|
481 454.1 590.2
|
0.27 0.27 0.19
|
0.44 0.44 0.32
|
1 × 95* 1 × 120 1 × 120*
|
11.5 14.2 12.9
|
1.6 1.6 1.6
|
1.8 1.8 1.8
|
19.9 22.8 21.5
|
1143 1454 1400
|
561.3 698.8 663.7
|
0.19 0.15 0.15
|
0.32 0.25 0.25
|
1 × 150 1 × 150* 1 × 185
|
15.8 14.5 17.6
|
1.8 1.8 2.0
|
1.8 1.8 1.8
|
24.8 23.5 27.0
|
1751 1721 2140
|
823.5 795.9 976.2
|
0.12 0.12 0.01
|
0.21 0.21 0.16
|
1 × 185* 1 × 240 1 × 240*
|
16.0 20.3 18.3
|
2.0 2.2 2.2
|
1.8 1.8 1.8
|
25.4 29.9 27.9
|
2020 2729 2567
|
915.6 1200 1121
|
0.01 0.08 0.08
|
0.16 0.13 0.13
|
1 × 300 1 × 300* 1 × 400
|
22.7 20.5 25.7
|
2.4 2.4 2.6
|
1.9 1.9 2.0
|
32.7 30.5 38.1
|
3363 3225 4596
|
1445 1369 2142
|
00.6 0.06 0.05
|
0.10 0.10 0.08
|
1 × 400* 1 × 500 1 × 500*
|
23.5 28.8 26.5
|
2.6 2.8 2.8
|
2.0 2.1 2.1
|
35.9 41.8 39.5
|
4461 5667 5584
|
2050 2574 2492
|
0.05 0.04 0.04
|
0.08 0.06 0.06
|
1 × 630 1 × 630* 1 × 800
|
32.5 29.9 36.6
|
2.8 2.8 2.8
|
2.3 2.3 2.4
|
46.3 43.7 50.9
|
7084 6878 8757
|
3132 3031 3789
|
0.03 0.03 0.02
|
0.05 0.05 0.04
| *表示导体为紧压圆形胶合导体。 *-Compacted stranded circular conductor. |
 |
0.6/1KV两芯交联聚乙烯绝缘聚氯乙烯护套电力电缆(YJV,YJLV) 0.6/1KV,2-core,XLPE Insulated,PVC Shezthed Power Cable
导体标称截面 Nom.cross-section of conductor
|
导体直径 Diammeter ofconductor
|
绝缘厚度 Insulation Thickness
|
护套厚度 Sheath thickness
|
电缆近似外径 Approx.overall diameterof cable
|
电缆近似重量 Approx.weighe of cable Kg/km
|
导体最大直流电阻 Max.d.cresistance (20 ℃ )Ω /km
|
试验电压 Test Voltage(a.c)
|
mm2
|
mm
|
mm
|
mm
|
mm
|
YJV
|
YJLV
|
YJV
|
YJLV
|
KV/5min
|
2 × 1.5 2 × 2.5 2 × 4
|
1.4 1.8 2.2
|
0.7 0.7 0.7
|
1.8 1.8 1.8
|
10.0 10.8 11.7
|
99.6 127.2 164.7
|
- 95.8 115
|
12.1 7.41 4.61
|
- 12.1 7.41
|
3.5
|
2 × 6 2 × 10 2 × 16
|
2.8 4.1 5.1
|
0.7 0.7 0.7
|
1.8 1.8 1.8
|
12.7 15.3 17.4
|
214.6 324.2 460.9
|
139.2 195.9 257.5
|
3.08 1.83 1.15
|
4.61 3.08 1.91
|
2 × 25 2 × 35 2 × 50**
|
6.4 7.6 5.6
|
0.9 0.9 1.0
|
1.8 1.8 1.8
|
20.8 23.1 19.6
|
691.7 907.4 1039
|
369.4 460.5 478.3
|
0.73 0.52 0.39
|
1.20 0.87 0.64
|
2 × 50 2 × 50* 2 × 70**
|
8.9 8.3 6.7
|
1.0 1.0 1.1
|
1.8 1.8 1.8
|
26.2 25.0 22.6
|
1194 1149 1456
|
588.6 559.8 646.6
|
0.39 0.39 0.27
|
0.64 0.64 0.44
|
2 × 70 2 × 70* 2 × 95**
|
10.7 9.8 8.1
|
1.1 1.1 1.1
|
1.8 1.8 2.0
|
30.6 28.8 25.8
|
1672 1576 1973
|
797.4 743.2 849.3
|
0.27 0.27 0.19
|
0.44 0.44 0.32
|
2 × 95 2 × 95* 2 × 120**
|
12.6 11.5 9
|
1.1 1.1 1.2
|
2.0 2.0 2.1
|
34.8 32.6 28.2
|
2265 2171 2459
|
1052 989.3 1042
|
0.19 0.19 0.15
|
0.32 0.32 0.25
|
2 × 120 2 × 120* 2 × 150**
|
14.2 12.9 11.7
|
1.2 1.2 1.4
|
2.1 2.1 2.2
|
38.6 36.0 34.6
|
2832 2713 3058
|
1299 1219 1309
|
0.15 0.15 0.12
|
0.25 0.25 0.21
|
2 × 150 2 × 150* 2 × 185**
|
15.8 14.5 12
|
1.4 1.4 1.6
|
2.2 2.2 2.3
|
42.7 40.2 36.2
|
3472 3398 3768
|
1589 1520 1579
|
0.12 0.12 0.10
|
0.21 0.21 0.16
|
2 × 185 2 × 185* 2 × 240
|
17.6 16.0 20.3
|
1.6 1.6 1.7
|
2.3 2.3 2.5
|
47.5 44.2 53.5
|
4307 4042 5637
|
1945 1800 2532
|
0.10 0.10 0.08
|
0.16 0.16 0.13
|
2 × 240* 2 × 300 2 × 300*
|
18.3 22.7 20.5
|
1.7 1.8 1.8
|
2.5 2.7 2.7
|
49.6 59.2 54.8
|
5264 6932 7345
|
2329 3037 3076
|
0.08 0.08 0.06
|
0.13 0.10 0.10
| *表示导体为紧压圆形胶合导体。 **表示导体为紧压扇形胶合导体。 *-Compacted stranded circular conductor. **-Compact sector shaped conductor. |
 |
0.6/1KV两芯交联聚乙烯绝缘钢带铠装聚氯乙烯护套电力电缆(YJV22,YJLV22) 0.6/1KV,2-Core,XLPE Insulated,Steel Tape Armoured,PVC Shezthed Power Cable
导体标称截面 Nom.cross-section of conductor
|
导体直径 Diammeter ofconductor
|
绝缘厚度 Insulation Thickness
|
护套厚度 Sheath thickness
|
电缆近似外径 Approx.overall diameterof cable
|
电缆近似重量 Approx.weighe of cable Kg/km
|
导体最大直流电阻 Max.d.cresis tance(20 ℃ ) Ω /km
|
试验电压 Test Voltage(a.c)
|
mm2
|
mm
|
mm
|
Mm
|
mm
|
YJV
|
YJLV
|
YJV
|
YJLV
|
KV/5min
|
2 × 2.5 2 × 4 2 × 6
|
1.8 2.2 2.8
|
0.7 0.7 0.7
|
1.8 1.8 1.8
|
12.6 13.5 14.5
|
218.8 265.3 325.4
|
187.5 215.6 250
|
7.41 4.61 3.08
|
12.1 7.41
|
0.35
|
2 × 10 2 × 16 2 × 25
|
4.1 5.1 6.4
|
0.7 0.7 0.9
|
1.8 1.8 1.8
|
17.1 19.2 22.6
|
447 602.1 863
|
318.8 398.7 540.7
|
1.83 1.15 0.73
|
4.61 3.08 1.91
|
2 × 35 2 × 50** 2 × 50
|
7.6 5.6 8.9
|
0.9 1.0 1.0
|
1.8 1.8 1.8
|
24.9 21.4 28.0
|
1099 1199 1412
|
651.7 638.8 806.8
|
0.52 0.39 0.39
|
1.20 0.87 0.64
|
2 × 50* 2 × 70** 2 × 70*
|
8.3 6.7 10.7
|
1.0 1.1 1.1
|
1.8 1.9 1.9
|
26.8 24.2 32.2
|
1357 1640 1927
|
767.5 830.4 1052
|
o.39 0.27 0.27
|
0.64 0.64 0.44
|
2 × 70* 2 × 95** 2 × 95
|
9.8 8.1 12.6
|
1.1 1.1 1.1
|
1.9 2.0 2.0
|
30.4 29 38
|
1815 2437 2898
|
981.8 1314 1685
|
0.27 0.19 0.19
|
0.44 0.44 0.32
|
2 × 95* 2 × 120** 2 × 120
|
11.5 9 14.2
|
1.1 1.2 1.2
|
2.0 2.1 2.1
|
35.8 31.4 41.8
|
2762 2966 3534
|
1581 1549 2001
|
0.19 0.15 0.15
|
0.32 0.32 0.25
|
2 × 120* 2 × 150** 2 × 150
|
12.9 11.7 15.8
|
1.2 1.4 1.4
|
2.1 2.3 2.3
|
39.2 38 46.1
|
3366 3699 4268
|
1872 1950 2385
|
0.15 0.12 0.12
|
0.25 0.25 0.21
|
2 × 150* 2 × 185** 2 × 185
|
14.5 12 17.6
|
1.4 1.6 1.6
|
2.3 2.4 2.4
|
43.6 39.6 50.9
|
4146 4435 5190
|
2268 2246 2828
|
0.12 0.10 0.10
|
0.21 0.21 0.16
|
2 × 185* 2 × 240 2 × 240*
|
16.0 20.3 18.3
|
1.6 1.7 1.7
|
2.4 2.6 2.6
|
47.6 56.9 53.0
|
4862 6589 6148
|
2620 3483 3213
|
0.10 0.80 0.80
|
0.16 0.16 0.13
|
2 × 300 2 × 300*
|
22.7 20.5
|
1.8 1.8
|
2.7 2.7
|
62.0 58.0
|
7995 7622
|
5101 3853
|
0.60 0.60
|
0.13 0.10 0.10
| *表示导体为紧压圆形胶合导体。 **表示导体为紧压扇形胶合导体。 *-Compacted stranded circular conductor. **-Compact sector shaped conductor. |
 |
|
|
0.6/1kv三芯交联聚乙烯绝缘聚氯乙烯护套电力电缆(YJV,YJLV) 6/1kv, 3-Core,XLPE Insulated PVC sheathed power cable
导体标称截面 Nom.cross-section of conductor
|
导体直径 Diammeter ofconductor
|
绝缘厚度 Insulation Thickness
|
护套厚度 Sheath thickness
|
电缆近似外径 Approx.over alldiameter of cable
|
电缆近似重量 Approx.weighe of cable Kg/km
|
导体最大直流电阻 Max.d.cresistance (20 ℃ )Ω /km
|
试验电压 Test Voltage(a.c)
|
mm2
|
mm
|
Mm
|
Mm
|
mm
|
YJV
|
YJLV
|
YJV
|
YJLV
|
KV/5min
|
3 × 1.5 3 × 2.5 3 × 4
|
1.4 1.8 2.2
|
0.7 0.7 0.7
|
1.8 1.8 1.8
|
10.4 11.3 12.2
|
120.8 158.5 210.4
|
- 111.4 135.8
|
12.1 7.41 4.61
|
- 12.1 7.41
|
0.35
|
3 × 6 3 × 10 3 × 16
|
2.8 4.1 5.1
|
0.7 0.7 0.7
|
1.8 1.8 1.8
|
13.4 16.1 18.4
|
280.2 430.7 623..6
|
167 238.3 318.2
|
3.08 1.83 1.15
|
4.61 3.08 1.91
|
3 × 25 3 × 35 3 × 50**
|
6.4 7.6 5.6
|
0.9 0.9 1.0
|
1.8 1.8 1.8
|
22.1 24.6 23.7
|
947.1 1254 1518
|
463.7 584 677
|
0.73 0.52 0.39
|
1.20 0.87 0.64
|
3 × 50 3 × 50* 3 × 70**
|
8.9 8.3 6.7
|
1.0 1.0 1.1
|
1.8 1.8 1.9
|
27.9 26.6 27.9
|
1660 1603 2143
|
752.2 718.7 929
|
0.39 0.39 0.27
|
0.64 0.64 0.44
|
3 × 70 3 × 70* 3 × 95**
|
10.7 9.8 8.1
|
1.1 1.1 1.1
|
1.9 1.9 2.0
|
32.8 30.9 31.3
|
2353 2224 2897
|
1041 975.2 1212
|
0.27 0.27 0.19
|
0.44 0.44 0.32
|
3 × 95 3 × 95* 3 × 120**
|
12.6 11.5 9
|
1.1 1.1 1.2
|
2.0 2.0 2.1
|
37.1 34.7 34.5
|
3179 3059 3628
|
1359 1288 1502
|
0.19 0.19 0.15
|
0.32 0.32 0.25
|
3 × 120 3 × 120* 3 × 150**
|
14.2 12.9 11.7
|
1.2 1.2 1.4
|
2.1 2.1 2.3
|
41.2 38.4 38.8
|
3983 3834 4496
|
1684 1593 1873
|
0.15 0.15 0.12
|
0.25 0.25 0.21
|
3 × 150 3 × 150* 3 × 185**
|
15.8 14.5 12
|
1.4 1.4 1.6
|
2.3 2.3 2.4
|
45.8 43.1 42.6
|
4909 4827 5576
|
2084 2010 2293
|
0.12 0.12 0.10
|
0.21 0.21 0.16
|
3 × 185 3 × 185* 3 × 240**
|
17.6 16.0 15.9
|
1.6 1.6 1.7
|
2.4 2.4 2.6
|
50.9 47.4 47.7
|
6104 5747 7240
|
2561 2384 2926
|
0.10 0.08 0.08
|
0.16 0.16 0.13
|
3 × 240 3 × 240* 3 × 300**
|
20.3 18.3 17.8
|
1.7 1.7 1.8
|
2.6 2.6 2.8
|
57.4 53.2 52.5
|
7941 7448 9013
|
3284 3045 3600
|
0.08 0.08 0.06
|
0.13 0.13 0.10
|
3 × 300 3 × 300* 3 × 400
|
22.7 20.5 25.7
|
1.8 1.8 2.0
|
2.8 2.8 3.0
|
63.4 58.7 71.1
|
9890 9463 12585
|
4049 3810 5114
|
0.06 0.06 0.05
|
0.10 0.10 0.08
|
3 × 400*
|
23.5
|
2.0
|
3.0
|
66.5
|
12225
|
4885
|
0.05
|
0.08
| *表示导体为紧压圆形绞合导线: **表示导体为紧压扇形导体 *Compacted ,stranded circular conductor; **-Compacted sector shaped conductor. |
 |
0.6/1kv 三芯交联聚乙烯绝缘钢带铠装聚氯乙烯护套电力电缆(YJV22,YJLV22) 6/1KV ,3-core XLPE insulated ,Steel tape aroured ,PVC sheathed power cable.
导体标称截面 Nom.cross-section of conductor
|
导体直径 Diammeter ofconductor
|
绝缘厚度 Insulation Thickness
|
护套厚度 Sheath thickness
|
电缆近似外径 Approx. overall diameterof cable
|
电缆近似重量 Approx.weighe of cable Kg/km
|
导体最大直流电阻 Max.d.cresistance (20 ℃ )Ω /km
|
试验电压 Test Voltage(a.c)
|
mm2
|
mm
|
Mm
|
Mm
|
mm
|
YJV
|
YJLV
|
YJV
|
YJLV
|
KV/5min
|
3 × 2.5 3 × 4 3 × 6
|
1.8 2.2 2.8
|
0.7 0.7 0.7
|
1.8 1.8 1.8
|
13.1 14.0 15.2
|
254.9 316.5 397.2
|
207.9 242 284.1
|
7.41 4.61 3.08
|
1.21 7.41 4.61
|
0.35
|
3 × 10 3 × 16 3 × 25
|
4.1 5.1 6.4
|
0.7 0.7 0.9
|
1.8 1.8 1.8
|
17.9 20.2 23.9
|
560.9 773.3 1130
|
368.5 468.2 646.2
|
1.83 1.15 0.73
|
3.08 1.91 1.20
|
3 × 35 3 × 50** 3 × 50
|
7.6 5.6 8.9
|
0.9 1.0 1.0
|
1.8 1.8 1.8
|
26.4 25.5 29.7
|
1458 1714 1893
|
787.9 873.3 985.2
|
0.52 0.39 0.39
|
0.87 0.64 0.64
|
3 × 50* 3 × 70** 3 × 70
|
8.3 6.7 10.7
|
1.0 1.1 1.1
|
1.8 2.0 2.0
|
28.4 31.3 36.2
|
1824 2663 2967
|
940.3 1449 1655
|
0.39 0.27 0.27
|
0.64 0.44 0.44
|
3 × 70* 3 × 95** 3 × 95
|
9.8 8.1 12.6
|
1.1 1.1 1.1
|
2.0 2.1 2.1
|
34.3 34.7 40.5
|
2801 3480 3872
|
1552 1794 2053
|
0.27 0.19 0.19
|
0.44 0.32 0.32
|
3 × 95* 3 × 120** 3 × 120
|
11.5 9 14.2
|
1.1 1.2 1.2
|
2.1 2.2 2.2
|
38.1 37.9 44.6
|
3708 4269 4753
|
1936 2143 2454
|
0.19 0.15 0.15
|
0.32 0.25 0.25
|
3 × 120* 3 × 150** 3 × 150
|
12.9 11.7 15.8
|
1.2 1.4 1.4
|
2.2 2.4 2.4
|
41.8 42.2 49.2
|
4549 5216 5762
|
2309 2592 2937
|
0.15 0.12 0.12
|
0.25 0.21 0.21
|
3 × 150* 3 × 185** 3 × 185
|
14.5 12 17.6
|
1.4 1.6 1.6
|
2.4 2.5 2.5
|
46.5 45.9 54.3
|
5628 6360 7051
|
2811 3077 3507
|
0.12 0.10 0.10
|
0.21 0.16 0.16
|
3 × 185* 3 × 240** 3 × 240
|
16.0 15.9 20.3
|
1.6 1.7 1.7
|
2.5 2.7 2.7
|
50.8 51.1 60.8
|
6626 8120 9006
|
3263 3806 4349
|
0.10 0.08 0.08
|
0.16 0.13 0.13
|
3 × 240* 3 × 300** 3 × 300
|
18.3 17.8 22.7
|
1.7 1.8 1.8
|
2.7 2.9 2.9
|
56.6 55.9 66.8
|
8432 9981 11067
|
4029 4567 5225
|
0.08 0.06 0.06
|
0.13 0.10 0.10
|
3× 300* 3 × 400 3 × 400*
|
20.5 25.7 23.5
|
1.8 2.0 2.0
|
2.9 3.1 3.1
|
62.1 74.5 69.9
|
10550 13904 13455
|
4896 6432 6114
|
0.06 0.05 0.05
|
0.10 0.08 0.08
| *表示导体为紧压圆形绞合导线; **表示导体为紧压扇形导体 *-Compacted ,stranded circular conductor , ** -Compacted sector shaped conductor |
 |
|
|
0.6/1kv四芯掉连聚乙烯绝缘聚氯乙烯护套电力电缆(YJV,YJLV) 0.6/1KV,4-Core,XLPE Insulated ,PVC Sheathed Power Cable
导体标称截面 Nom.cross-section of conductor
|
导体直径 Diammeter ofconductor
|
绝缘厚度 Insulation Thickness
|
护套厚度 Sheath thickness
|
电缆近似外径 Approx. overall diameterof cable
|
电缆近似重量 Approx.weighe of cable Kg/km
|
导体最大直流电阻 Max.d.cresistance (20 ℃ )Ω /km
|
试验电压 Test Voltage(a.c)
|
mm2
|
mm
|
Mm
|
Mm
|
mm
|
YJV
|
YJLV
|
YJV
|
YJLV
|
KV/5min
|
4 × 1.5 4 × 2.5 4 × 4
|
1.4 1.8 2.2
|
0.7 0.7 0.7
|
1.8 1.8 1.8
|
11.1 12.1 13.2
|
145.7 194.3 261.6
|
- 131.5 162.2
|
12.1 7.41 4.61
|
- 12.1 7.41
|
0.35
|
4 × 6 4 × 10 4 × 16
|
2.8 4.1 5.1
|
0.7 0.7 0.7
|
1.8 1.8 1.8
|
14.5 17.6 20.1
|
352.4 547.3 799.1
|
201.5 290.7 392.3
|
3.08 1.83 1.15
|
4.61 3.08 1.91
|
4 × 25 4 × 35 4 × 50**
|
6.4 7.6 5.6
|
0.9 0.9 1.0
|
1.8 1.8 1.8
|
24.3 27.1 26.2
|
1222 1626 2005
|
577.6 731.8 884.5
|
0.73 0.52 0.39
|
1.20 0.87 0.64
|
4 × 50 4 × 50* 4 × 70**
|
8.9 8.3 6.7
|
1.0 1.0 1.1
|
1.8 1.8 1.9
|
31.0 29.5 31.9
|
2172 2098 2855
|
961.1 919.2 1236
|
0.39 0.39 0.27
|
0.64 0.64 0.44
|
4 × 70 4 × 70* 4 × 95**
|
10.7 9.8 8.1
|
1.1 1.1 1.1
|
1.9 1.9 2.0
|
36.4 34.2 35.9
|
3080 2913 3843
|
1331 1248 1595
|
0.27 0.27 0.19
|
0.44 0.44 0.32
|
4 × 95 4 × 95* 4 × 120**
|
12.6 11.5 9
|
1.1 1.1 1.2
|
2.0 2.0 2.1
|
41.2 38.6 39.9
|
4166 4014 4820
|
1740 1651 1985
|
0.19 0.19 0.15
|
0.32 0.32 0.25
|
4 × 120 4 × 120* 4 × 150**
|
14.2 12.9 11.7
|
1.2 1.2 1.4
|
2.1 2.1 2.3
|
46.0 42.8 44
|
5244 5052 5931
|
2178 2064 2433
|
0.15 0.15 0.12
|
0.25 0.25 0.21
|
4 × 150 4 × 150* 4 × 185**
|
15.8 14.5 12
|
1.4 1.4 1.6
|
2.3 2.3 2.4
|
50.9 47.9 48.6
|
6435 6336 7367
|
2669 2579 2990
|
0.12 0.12 0.10
|
0.21 0.21 0.16
|
4 × 185 4 × 185* 4 × 240**
|
17.6 16.0 15.9
|
1.6 1.6 1.7
|
2.4 2.4 2.6
|
56.8 52.9 54.1
|
8034 7569 9540
|
3310 3085 3787
|
0.10 0.08 0.08
|
0.16 0.16 0.13
|
4 × 240 4 × 240* 4 × 300**
|
20.3 18.3 17.8
|
1.7 1.7 1.8
|
2.6 2.6 2.8
|
64.0 59.3 60.1
|
10452 9809 11888
|
4242 3939 4670
|
0.08 0.08 0.06
|
0.13 0.13 0.10
|
4 × 300 4 × 300* 4 × 400
|
22.7 20.5 25.7
|
1.8 1.8 2.0
|
2.8 2.8 3.0
|
70.8 65.5 79.6
|
13017 12467 16600
|
5228 4929 6637
|
0.06 0.06 0.05
|
0.10 0.10 0.08
|
4 × 400*
|
23.5
|
2.0
|
3.0
|
74.4
|
16139
|
6351
|
0.05
|
0.08
| *表示导体为紧压圆形绞合导线; **表示导体为紧压扇形导体 *-Compacted ,stranded circular conductor ; **-Compacted sector shaped conductor |
|
0.6/1kv四芯交联聚乙烯绝缘钢带铠装聚氯乙烯护套电力电缆(YJV22,YJLV22) 0.6/1KV,4-Core ,XLPE Insulated,Steel Tape Armoured ,PVC Sheathed Power Cable.
导体标称截面 Nom.cross-section of conductor
|
导体直径 Diammeter ofconductor
|
绝缘厚度 Insulation Thickness
|
护套厚度 Sheath thickness
|
电缆近似外径 Approx. overall diameter of cable
|
电缆近似重量 Approx.weighe of cable Kg/km
|
导体最大直流电阻 Max.d.cresistance (20 ℃ )Ω /km
|
试验电压 Test Voltage(a.c)
|
mm2
|
mm
|
Mm
|
Mm
|
mm
|
YJV22
|
YJLV22
|
YJV22
|
YJLV22
|
KV/5min
|
4 × 1.5 4 × 2.5 4 × 4
|
1.4 1.8 2.2
|
0.7 0.7 0.7
|
1.8 1.8 1.8
|
12.9 13.9 15.0
|
241 299 377.2
|
- 236.3 277.8
|
12.1 7.41 4.61
|
- 12.1 7.41
|
0.35
|
4 × 6 4 × 10 4 × 16
|
2.8 4.1 5.1
|
0.7 0.7 0.7
|
1.8 1.8 1.8
|
16.3 19.4 21.9
|
480.2 690.1 964.2
|
329.3 433.6 557.4
|
3.08 1.83 1.15
|
4.61 3.08 1.91
|
4 × 25 4 × 35 4 × 50**
|
6.4 7.6 5.6
|
0.9 0.9 1.0
|
1.8 1.8 1.8
|
26.1 28.9 30
|
1424 1851 2512
|
779.1 957.4 1391
|
0.73 0.52 0.39
|
1.20 0.87 0.64
|
4 × 50 4 × 50* 4 × 70**
|
8.9 8.3 6.7
|
1.0 1.0 1.1
|
1.8 1.8 1.9
|
34.8 33.3 35.3
|
2272 2669 3443
|
1561 1491 1824
|
0.39 0.39 0.27
|
0.64 0.64 0.44
|
4 × 70 4 × 70* 4 × 95**
|
10.7 9.8 8.1
|
1.1 1.1 1.1
|
1.9 1.9 2.0
|
39.8 37.6 39.3
|
3761 3552 4511
|
2012 1887 2264
|
0.27 0.27 0.19
|
0.44 0.44 0.32
|
4 × 95 4 × 95* 4 × 120**
|
12.6 11.5 9
|
1.1 1.1 1.2
|
2.0 2.0 2.1
|
44.6 42.0 43.3
|
4936 4733 5560
|
2510 2371 2725
|
0.19 0.19 0.15
|
0.32 0.32 0.25
|
4 × 120 4 × 120* 4 × 150**
|
14.2 12.9 11.7
|
1.2 1.2 1.4
|
2.1 2.1 2.3
|
49.4 46.2 47.4
|
6101 5848 6747
|
3035 2860 3249
|
0.15 0.15 0.12
|
0.25 0.25 0.21
|
4 × 150 4 × 150* 4 × 185**
|
15.8 14.5 12
|
1.4 1.4 1.6
|
2.3 2.3 2.4
|
54.3 51.3 52
|
7384 7226 8265
|
3618 3470 3886
|
0.12 0.12 0.10
|
0.21 0.21 0.16
|
4 × 185 4 × 185* 4 × 240**
|
17.6 16.0 15.9
|
1.6 1.6 1.7
|
2.4 2.4 2.6
|
60.2 56.3 57.3
|
9089 8548 10514
|
4365 4064 4761
|
0.10 0.08 0.08
|
0.16 0.16 0.13
|
4 × 240 4 × 240* 4 × 300**
|
20.3 18.3 17.8
|
1.7 1.7 1.8
|
2.6 2.6 2.8
|
67.2 62.5 63.5
|
11611 10882 12996
|
5401 5010 5778
|
0.08 0.08 0.06
|
0.13 0.13 0.10
|
4 × 300 4 × 300* 4 × 400
|
22.7 20.5 25.7
|
1.8 1.8 2.0
|
2.8 2.8 3.0
|
74.2 68.9 83
|
14330 13679 18073
|
6541 6141 8110
|
0.06 0.06 0.05
|
0.10 0.10 0.08
|
4 × 400*
|
23.5
|
2.0
|
3.0
|
77.8
|
15512
|
7725
|
0.05
|
0.08
| *表示导体为紧压圆形绞合导线; **表示导体为紧压扇形导体 *-Compacted ,stranded circular conductor ; **-Compacted sector shaped conductor |
|
|
|
|
|
|
|
|
'
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
电缆载流量 current carruing capacity of cable ·空气中敷设 In air 非铠装型电缆 Unarmored cable;
导体 conductor
|
导体标称截面 Nominal cross-section of conductor mm2
|
单芯 single-core
|
二芯 2-core
|
三芯 3-core
|
3+1 芯 3+1-core
|
四芯 4core
|
铜导体 Copper conductor
|
1.5
|
20
|
19
|
23
|
19
|
26
|
2.5
|
26
|
26
|
30
|
26
|
35
|
4
|
39
|
37
|
44
|
35
|
44
|
6
|
48
|
46
|
52
|
44
|
52
|
10
|
65
|
61
|
70
|
57
|
70
|
16
|
87
|
80
|
87
|
74
|
87
|
25
|
122
|
111
|
113
|
100
|
113
|
35
|
152
|
139
|
135
|
126
|
135
|
50
|
183
|
165
|
161
|
152
|
161
|
70
|
235
|
218
|
196
|
191
|
196
|
95
|
296
|
261
|
235
|
235
|
235
|
120
|
348
|
305
|
265
|
274
|
265
|
150
|
400
|
348
|
300
|
313
|
300
|
185
|
461
|
400
|
339
|
365
|
339
|
240
|
544
|
479
|
396
|
435
|
396
|
300
|
596
|
522
|
452
|
522
|
457
|
铝导体 Aluminum conductor
|
2.5
|
22
|
22
|
26
|
0
|
26
|
4
|
30
|
28
|
35
|
26
|
35
|
6
|
39
|
37
|
39
|
35
|
39
|
10
|
52
|
48
|
52
|
44
|
52
|
16
|
70
|
65
|
70
|
57
|
70
|
25
|
100
|
87
|
87
|
78
|
87
|
35
|
122
|
113
|
104
|
96
|
104
|
50
|
148
|
131
|
122
|
113
|
122
|
70
|
187
|
165
|
152
|
148
|
152
|
95
|
239
|
209
|
183
|
178
|
183
|
120
|
278
|
252
|
204
|
209
|
204
|
150
|
322
|
287
|
231
|
239
|
231
|
185
|
361
|
322
|
262
|
278
|
265
|
240
|
426
|
383
|
309
|
335
|
309
|
300
|
479
|
487
|
361
|
392
|
348
| |
铠装型电缆 Armoured cable
导体 conductor
|
导体标称截面 Nominal cross-section of conductor mm2
|
二芯 2-core
|
三芯 3-core
|
3+1 芯 3+1-core
|
四芯 4core
|
铜导体 Copper conductor
|
2.5
|
26
|
30
|
26
|
35
|
4
|
37
|
44
|
35
|
44
|
6
|
46
|
52
|
44
|
52
|
10
|
61
|
70
|
57
|
70
|
16
|
80
|
87
|
74
|
87
|
25
|
111
|
113
|
100
|
113
|
35
|
139
|
135
|
126
|
135
|
50
|
165
|
161
|
152
|
161
|
70
|
218
|
196
|
191
|
196
|
95
|
261
|
235
|
235
|
235
|
120
|
305
|
265
|
274
|
265
|
150
|
348
|
300
|
313
|
300
|
185
|
400
|
339
|
365
|
339
|
240
|
479
|
396
|
435
|
396
|
300
|
522
|
452
|
522
|
457
|
铝导体 Aluminum conductor
|
2.5
|
22
|
26
|
0
|
26
|
4
|
28
|
35
|
26
|
35
|
6
|
37
|
39
|
35
|
39
|
10
|
48
|
52
|
44
|
52
|
16
|
65
|
70
|
57
|
70
|
25
|
87
|
87
|
78
|
87
|
35
|
113
|
104
|
96
|
104
|
50
|
131
|
122
|
113
|
122
|
70
|
165
|
152
|
148
|
152
|
95
|
209
|
183
|
178
|
183
|
120
|
252
|
204
|
209
|
204
|
150
|
287
|
231
|
239
|
231
|
185
|
322
|
262
|
278
|
265
|
240
|
383
|
309
|
335
|
309
|
|
300
|
487
|
361
|
392
|
348
| |
·直埋敷设 Direct in the ground 非铠装型电缆 Unarmored cable;
导体 conductor
|
导体标称截面 Nominal cross-section of conductor mm2
|
单芯 single-core
|
二芯 2-core
|
三芯 3-core
|
3+1 芯 3+1-core
|
四芯 4core
|
铜导体 Copper conductor
|
1.5
|
33
|
|
|
|
|
2.5
|
45
|
|
|
|
|
4
|
60
|
|
|
|
|
6
|
70
|
|
|
|
|
10
|
95
|
|
|
|
|
16
|
125
|
|
|
|
|
25
|
160
|
|
|
|
|
35
|
190
|
|
|
|
|
50
|
225
|
|
|
|
|
70
|
280
|
|
|
|
|
95
|
335
|
|
|
|
|
120
|
380
|
|
|
|
|
150
|
425
|
|
|
|
|
185
|
480
|
|
|
|
|
240
|
555
|
|
|
|
|
300
|
615
|
|
|
|
|
铝导体 Aluminum conductor
|
2.5
|
35
|
32
|
25
|
|
25
|
4
|
50
|
45
|
30
|
40
|
30
|
6
|
55
|
50
|
40
|
45
|
40
|
10
|
75
|
70
|
50
|
60
|
50
|
16
|
100
|
90
|
65
|
80
|
65
|
25
|
130
|
120
|
90
|
100
|
90
|
35
|
150
|
140
|
110
|
120
|
110
|
50
|
180
|
160
|
130
|
140
|
130
|
70
|
225
|
200
|
170
|
175
|
170
|
95
|
270
|
230
|
205
|
210
|
205
|
120
|
305
|
260
|
240
|
235
|
240
|
150
|
340
|
300
|
275
|
265
|
275
|
185
|
375
|
340
|
320
|
301
|
320
|
240
|
435
|
400
|
385
|
355
|
385
|
300
|
496
|
510
|
430
|
410
|
450
| |
铠装型电缆 Armoured cable;
导体 conductor
|
导体标称截面 Nominal cross-section of conductor mm2
|
二芯 2-core
|
三芯 3-core
|
3+1 芯 3+1-core
|
四芯 4core
|
铜导体 Copper conductor
|
2.5
|
40
|
30
|
35
|
30
|
4
|
55
|
40
|
50
|
40
|
6
|
65
|
50
|
60
|
50
|
10
|
90
|
65
|
80
|
65
|
16
|
110
|
85
|
100
|
85
|
25
|
140
|
115
|
130
|
115
|
35
|
180
|
145
|
155
|
145
|
50
|
210
|
175
|
185
|
175
|
70
|
250
|
220
|
225
|
220
|
95
|
285
|
270
|
270
|
270
|
120
|
330
|
315
|
305
|
315
|
150
|
375
|
360
|
345
|
360
|
185
|
420
|
420
|
390
|
420
|
240
|
500
|
500
|
455
|
500
|
300
|
580
|
550
|
520
|
585
|
铝导体 Aluminum conductor
|
2.5
|
32
|
25
|
|
25
|
4
|
45
|
30
|
40
|
30
|
6
|
50
|
40
|
45
|
40
|
10
|
70
|
50
|
60
|
50
|
16
|
90
|
65
|
80
|
65
|
25
|
120
|
90
|
100
|
90
|
35
|
140
|
110
|
120
|
110
|
50
|
160
|
130
|
140
|
130
|
70
|
200
|
170
|
175
|
170
|
95
|
230
|
205
|
210
|
205
|
120
|
260
|
240
|
235
|
240
|
150
|
300
|
275
|
265
|
275
|
185
|
340
|
320
|
301
|
320
|
240
|
400
|
385
|
355
|
385
|
|
300
|
510
|
430
|
410
|
450
| |
电缆敷设运行条件 ·在空气中的敷设 In air 1.单芯电缆平行敷设时中心距离:185 mm2 及以下为电缆直径的2倍;240 mm2及以上为90mm. 2. 围环境空气温度:40℃。 3.导体的长期最高工作温度:90℃。 ·The cingle-core cables are paralled laid , the distance between the cable center is 2 times of the cable diameter for cross-section of conductor<=185 mm2 and 90 mm for cross-section of conductor >=240 mm2 2. Ambient air temperture :40℃ 3. Max. continous operating wemperature of conductor: 90℃。
不同环境温度下载流量的修正系数: Current rating factors for variation in ambient air temperature:
环境温度 Ambient temperature
|
20 ℃
|
25℃
|
30℃
|
35℃
|
40℃
|
45℃
|
修正系数 Rating factor
|
1.29
|
1.22
|
1.15
|
1.08
|
1.0
|
0.91
| |
·直埋敷设 Direct in the ground 1. 单芯电缆不接触敷设时电缆中心距离为电缆直径的2倍 2. 土壤温度:25℃。 3. 导体的长期最高工作温度: 90℃。 4. 土壤热阻系数: 1.0℃.m/w. 5. 直埋深度:0.7m. ·The single-core cables are installed separately , the distance between the cable center is 2 times of the cable Diameter. 2. Soil temperature :25℃ 3. Max. continous operating temperature of conductor:90℃ 4. Depth of laying :0.7 m
土壤温度 Soil temperature |
20 ℃ |
25℃ |
30℃ |
35℃ |
40℃ |
修正系数 Rating factor |
1.04 |
1.0 |
0.96 |
0.92 |
0.87 | |
|